STUDY ON DETERMINING THE GEOMETRIC DIMENSIONS OF COLLIMATORS USED IN GAMMA SPECTROMETER MEASUREMENT USING THE MCNP4C2 CODE

Main Article Content

Võ Xuân Ân

Abstract

 


For many years, lead collimators have been widely used to generate narrow gamma beams in gamma spectroscopy measurements. Changing the size of the collimator is a time-consuming and costly task, which is difficult to perform in practical experiments to determine the appropriate size. Nowadays, there are many useful and reliable Monte Carlo simulation tools, including the MCNP4C2 simulation code, which allows designing experiments with flexible physical parameters, the calculation results are in good agreement with the experiment, especially saving time and cost. In this work, the Monte Carlo simulation code MCNP4C2 was used to build a simulation model to study the determination of the geometric size of the lead collimator. The results show that, for a circular collimator, the outer radius taken as the detector crystal radius and the length taken as the source-detector distance are suitable choices.

Article Details

Section
Information Technology, Electricity, Electronic